Example:
(X8)
Interface for START/ STOP - SLAVE indicator, potential free alarm relay contacts and Digital Slave
Indicator.
After each sounding the LAZ 5100 transmits depth information to the Digital Slave Display
interface (15 to 60 times per minute, depending upon the measuring range selected) in NMEA,
Version 2.00 format. The DPT (Depth) and DBT (Depth Below Transducer) sentences are as
follows:
DPT (Depth)
$ZAZDA 184533.20 20,12,1995 12,15 62, , , * <CR><LF>
Checksum
Difference 12 hrs 15 mins
Date 20th Dec 1995
UTC=18:45:33.20 s
Data are originating from
an atomic clock
$SDDPT x.x -x.x xx hh, , , ,* <CR><LF
>
Checksum
Distance transducer-keel
in metres
Depth in metres
Range Scale